flexAI Hardware

flexAI hardware manual

AIXpressor - Overview

AIXpressor - Overview

Overview

AIXpressor_FrontDropShadow_2019-10_2000PX.png

Introduction

The AIXpressor is a flexible, software-defined audio processing and interface platform. Unlike traditional stand-alone processors, where functionality is closely tied to fixed hardware and firmware, AIXpressor runs the flexAI software platform. This allows processing functions, codecs, metadata tools, interfaces, and other features to be added or extended through software updates and licensing.

AIXpressor combines real-time audio processing with a wide range of physical and IP-based audio interfaces. Native Audio over IP support includes Livewire+, AES67, and SMPTE ST 2110, while conventional interfaces such as analog audio, AES3, and MADI provide connectivity to existing baseband infrastructure.

This makes AIXpressor suitable both as a stand-alone audio processor and as an interface between traditional audio systems and IP-based environments.

Hardware

AIXpressor is built around a high-performance x86 multi-core processing platform. The main processor handles real-time audio processing, measurement, routing, codecs, Audio over IP, system services, and the web-based user interface.

A high-performance FPGA manages the connection between the processing system and the physical audio interfaces.

The main hardware features include:

On-board Audio Interfaces

AIXpressor includes the following audio interfaces as standard:

MADI and tieLight require different SFP module types. Refer to the corresponding interface section for details.

Expansion Slots

Four expansion slots allow additional physical interfaces to be installed. Each slot provides connectivity for high-channel-count audio applications.

Available interface modules may include:

The exact channel count and capabilities depend on the installed interface module.

Software

AIXpressor runs the flexAI software platform. flexAI separates audio processing functionality from the physical hardware, allowing new applications and features to be added as the software platform evolves.

Processing modules are available in different channel configurations where applicable, ranging from mono and stereo to surround and immersive formats such as 7.1.4.

Available and optional processing functions may include:

The exact set of available functions depends on the installed flexAI software version and licenses.

Audio I/O and Routing

AIXpressor provides analog, AES3, MADI, and Audio over IP connectivity as part of its standard hardware. Additional interfaces can be added using the four expansion slots.

The built-in AES3 and analog interfaces can each be configured as either 8 Inputs / 8 Outputs or 4 Inputs / 12 Outputs. The 4-in / 12-out configuration provides additional output capacity for multichannel and immersive audio formats such as 7.1.4.

The two SFP interfaces can be configured for MADI or the proprietary Jünger Audio tieLight interface. tieLight provides a high-channel-count, low-latency optical connection between compatible systems.

Audio from physical and IP-based interfaces is available to the internal flexAI routing system. Routing operates at channel level, allowing signals from different interface types to be freely combined, rearranged, processed, and routed to available destinations.

Routing configurations can also be stored and recalled as presets.

Control

AIXpressor is primarily operated through its browser-based web interface.

For integration with external control, automation, and monitoring systems, flexAI supports protocols including:

The available control functions may depend on the installed software version and system configuration.

Applications and Use Cases

The flexible combination of processing, routing, conventional audio interfaces, and Audio over IP allows AIXpressor to be used in a wide range of broadcast and professional audio applications.

Typical applications include:

AIXpressor can operate as a dedicated stand-alone processor or as part of a larger flexAI installation with multiple interconnected processing systems.

AIXpressor - Overview

Physical Installation

Physical Installation

AIXpressor is a 1RU, 19-inch rack-mount unit intended for permanent installation in a standard equipment rack. Secure the unit to the rack using four suitable rack screws.

AIXpressor is actively cooled. Viewed from the front, cooling air is drawn in on the left-hand side of the unit and exhausted on the right-hand side. Make sure that the corresponding ventilation openings are not obstructed and that sufficient airflow is available around the unit.

Additional free rack space above or below the AIXpressor is normally not required, provided that adequate ventilation is maintained. In installations with high ambient temperatures or restricted airflow, additional spacing may help improve cooling.

Power

AIXpressor is equipped with two redundant power supplies, each with its own IEC mains inlet and On/Off switch.

For redundant operation, connect both power supplies. If one power supply or its mains feed fails, the second supply can continue to power the unit.

For installations requiring maximum availability, connect the two power supplies to independent mains circuits whenever possible. Ideally, the circuits should also use separate UPS feeds or other suitable backup power arrangements. This helps maintain operation not only in case of a power supply failure, but also if one mains circuit becomes unavailable.

Each power supply can be switched on and off independently.

The power supply modules are located inside the chassis. Replacing a power supply therefore requires opening the unit. Although replacement may technically be possible while the second power supply remains active, this is generally not practical while the unit is installed in a rack.

Important - Please read Safety Informationon proper grounding and electrical safety.

AIXpressor - Overview

Front and Rear Panel

Front Panel

AIXpressor_FrontDropShadow_2019-10_2000PX.png

The AIXpressor front panel provides direct access to the following connections and controls:

Rear Panel

AIXpressor Rear

The rear panel provides power, network, synchronization, audio I/O, and expansion connections.

Power

For maximum redundancy, connect the two power supplies to independent mains circuits as described in the Power section.

Network

The assignment of the network ports depends on the system and AoIP configuration.

USB and Service

MADI / tieLight

Two SFP cages provide the built-in MADI / tieLight interfaces.

The operating mode of each interface is selected in the software. MADI and tieLight require different SFP module types.

Depending on the installed module, MADI connections can be provided as optical single-mode, optical multi-mode, or coaxial BNC interfaces.

External Synchronization

A 75 Ω BNC connector provides the external synchronization input.

Supported synchronization formats include:

AES3 I/O

The built-in AES3 interface uses a 25-pin D-Sub female connector.

It can be configured as:

AES3 is also commonly referred to as AES/EBU.

Analog I/O

The built-in analog interfaces use two 25-pin D-Sub female connectors:

This allows the complete analog interface to operate as either:

Expansion Slots

AIXpressor provides four interface expansion slots, IF 1 – IF 4, for optional interface boards.

Each slot supports up to 64 bidirectional audio channels, depending on the installed interface module.

Available expansion modules include interfaces for applications such as SDI, MADI, Dante, AES3, analog audio, and microphone inputs.

AIXpressor - Overview

Network Connections

General Network Considerations

By default, DHCP is enabled on all AIXpressor network interfaces. When connected to a network with an active DHCP server, each interface automatically obtains an IP configuration.

The IP address assigned to LAN 1 CTRL is shown on the front-panel display. If no DHCP server is available, a static IPv4 address can be configured for LAN 1 CTRL from the front panel to establish an initial network connection.

AIXpressor also supports Zero Configuration Networking (mDNS/Bonjour) and can therefore be reached by its .local host name on compatible networks.

Note - The network settings available from the front panel apply to \*\*LAN 1 CTRL\*\* only.

Note - When integrating the AIXpressor into a managed network, coordinate the required IP addressing and network settings with the network administrator.

Accessing the Web Interface

To connect using the IP address shown on the front panel, enter the address in a web browser:

https://<IP-address>

If the AIXpressor is using its factory-installed self-signed certificate, the browser may initially display a certificate warning.

If your computer supports mDNS, the unit can alternatively be reached using its .local host name.

For example:

https://AIXpressor-00080.local

The exact host name is shown on the front-panel display.

The AIXpressor user interface is web-based and can be accessed with a modern desktop or mobile web browser.

Setting a Static IP Address from the Front Panel

A static IP address can be configured from the touch-sensitive front panel. This is useful when no DHCP server is available or when the AIXpressor must first be placed on a specific network before the web interface can be reached.

  1. Open the Menu on the front panel.

Front Panel Menu

  1. Select Network to display the LAN 1 CTRL settings.

Front Panel Network

  1. Select Edit Static IP Address.
  2. Set the required IP Address and Subnet Mask.

Front Panel IP

  1. Select Apply to save the configuration.
AIXpressor - Overview

Safety Information

Critical information - Please read carefully.

Safety Information

Electrical Safety

Service Safety

Service work should only be carried out by qualified personnel.

Before opening or servicing the unit:

  1. Switch off both power supplies.
  2. Disconnect both mains power cords.
  3. Make sure that the power cords cannot be reconnected accidentally while service work is in progress.

Do not perform service work on the unit while it is connected to mains power unless the procedure specifically requires this and is carried out by suitably qualified personnel.

Installation and Operation

Internal Battery

AIXpressor contains an internal lithium battery.

The battery must only be replaced with the specified type and by qualified service personnel. Using an incorrect battery type or installing it incorrectly may present a risk of fire or explosion.

AIXpressor - Technical Data

AIXpressor - Technical Data

General

Audio Sample Rate

AES/EBU Inputs

AES/EBU Outputs

SFP Sockets

SFP MADI Module

SFP tieLight Module

Sync Input

Network Interfaces

USB Interfaces

Expansion Slots

Power Supplies

Environmental

Physical

AIXpressor - Technical Data

D-Sub DB-25 Pin Assignments

AES I/O

I/O Mode can be configured in the software to set the physical connectors between 8×8 I/O channels and 4×12 I/O channels.
Please note: AES3 is running digital audio in channel pairs (stereo) on one physical pin.

Pin (Female Connector)

I/O Mode: 8×8 I/O

I/O Mode: 4×12 I/O

1

Output Pair 4 +

Output Pair 4 +

2

Ground

Ground

3

Output Pair 3 -

Output Pair 3 -

4

Output Pair 2 +

Output Pair 2 +

5

Ground

Ground

6

Output Pair 1 +

Output Pair 1 +

7

Input Pair 4 +

Output Pair 6 +

8

Ground

Ground

9

Input Pair 3 -

Output Pair 5 -

10

Input Pair 2 +

Input Pair 2 +

11

Ground

Ground

12

Input Pair 1 -

Input Pair 1 -

13

Not Used

Not Used

14

Output Pair 4 -

Output Pair 4 -

15

Output Pair 3 +

Output Pair 3 +

16

Ground

Ground

17

Output Pair 2 -

Output Pair 2 -

18

Output Pair 1 +

Output Pair 1 +

19

Ground

Ground

20

Input Pair 4 -

Output Pair 6 -

21

Input Pair 3 +

Output Pair 5 +

22

Ground

Ground

23

Input Pair 2 -

Input Pair 2 -

24

Input Pair 1 +

Input Pair 1 +

25

Ground

Ground

Analog I/O

I/O Mode can be configured in the software to set the physical connectors between 8×8 I/O channels and 4×12 I/O channels. The outputs on the Analog I/O connectors thus are labeled to be the upper 4 of the total 12 outputs.

Pin (Female Connector)

Mode: 8×8 I/O

Mode: 4×12 I/O

1

Input 8 +

Output 12 +

2

Ground

Ground

3

Input 7 -

Output 11 -

4

Input 6 +

Output 10 +

5

Ground

Ground

6

Input 5 +

Output 9 +

7

Input 4 +

Input 4 +

8

Ground

Ground

9

Input 3 -

Input 3 -

10

Input 2 +

Input 2 +

11

Ground

Ground

12

Input 1 -

Input 1 -

13

Not Used

Not Used

14

Input 8 -

Output 12 -

15

Input 7 +

Output 11 +

16

Ground

Ground

17

Input 6 -

Output 10 -

18

Input 5 +

Output 9 +

19

Ground

Ground

20

Input 4 -

Input 4 -

21

Input 3 +

Input 3 +

22

Ground

Ground

23

Input 2 -

Input 2 -

24

Input 1 +

Input 1 +

25

Ground

Ground

Analog Outputs

Pin (Female Connector)

Function

1

Output 8 +

2

Ground

3

Output 7 -

4

Output 6 +

5

Ground

6

Output 5 -

7

Output 4 +

8

Ground

9

Output 3 -

10

Output 2 +

11

Ground

12

Output 1 -

13

Not Used

14

Output 8 -

15

Output 7 +

16

Ground

17

Output 6 -

18

Output 5 +

19

Ground

20

Output 4 -

21

Output 3 +

22

Ground

23

Output 2 -

24

Output 1 +

25

Ground

AIXpressor - Technical Data

AES3 I/O Relay Bypass Settings

AES3 I/O Relay Bypass

The AES3 inputs and outputs provide a relay bypass feature that, when enabled, activates in the event of a power failure or upon a deliberate command from the GUI.

In order to enable the relay bypass feature, the jumpers for each AES3 pair (A) must be in place as shown in Figure 1 below. Removing the jumpers prevents relay bypass from occurring.


Figure 1 - Relay Bypass

AIXpressor - Technical Data

Option Board AoIP / Dante™

Option Board AoIP / Dante™ (O_DAP_Dante_a)

Standards

Audio

Important - Not all sample rates are supported by the host system, please refer to the respective information.

Inputs and Outputs

General Features

AIXpressor - Technical Data

Option Board SDI I/O

Option Board SDI I/O (O_DAP_SDI_a)

Standards

Video Data Rate

Video Formats

Video Delay

Audio

Metadata (RDD6)

BNC Input

BNC Output

Latency

General Features

AIXpressor - Technical Data

Option Board 8 Ch Analog Out

Option Board 8 Ch Analog Out (O_DAP_8DA_a)

Audio

Important - Not all sample rates are supported by the host system, please refer to the respective information.

Analog Outputs

General Features

AIXpressor - Technical Data

Option Board 4 Ch Analog I/O

Option Board 4 Ch Analog I/O (O_DAP_ADDA_a)

Audio

Important - Not all sample rates are supported by the host system, please refer to the respective information.

Analog Inputs

Analog Outputs

General Features

AIXpressor - Technical Data

Option Board 4 Ch Microphone Inputs

Option Board 4 Ch Microphone Inputs (O_AIX_4MIC_a)

Analog Inputs

Connector DB-25 Pin Assignment

Pin (Female Connector)

Function

1

Not Used

2

Ground

3

Not Used

4

Not Used

5

Ground

6

Not Used

7

Input 4 +

8

Ground

9

Input 3 -

10

Input 2 +

11

Ground

12

Input 1 -

13

Not Used

14

Not Used

15

Not Used

16

Ground

17

Not Used

18

Not Used

19

Ground

20

Input 4 -

21

Input 3 +

22

Ground

23

Input 2 -

24

Input 1 +

25

Ground

AIXpressor - Technical Data

Option Board AES/EBU I/O

Option Board AES/EBU I/O (O_DAP_AES_a)

Standards

Audio

Important - Not all sample rates are supported by the host system, please refer to the respective information.

Inputs

Outputs

Connector DB-25 Pin Assignment

Please note: AES3 is running digital audio in channel pairs (stereo) on one physical pin.

Pin (Female Connector)

Function

1

Output Pair 4 +

2

Ground

3

Output Pair 3 -

4

Output Pair 2 +

5

Ground

6

Output Pair 1 +

7

Input Pair 4 +

8

Ground

9

Input Pair 3 -

10

Input Pair 2 +

11

Ground

12

Input Pair 1 -

13

Not Used

14

Output Pair 4 -

15

Output Pair 3 +

16

Ground

17

Output Pair 2 -

18

Output Pair 1 +

19

Ground

20

Input Pair 4 -

21

Input Pair 3 +

22

Ground

23

Input Pair 2 -

24

Input Pair 1 +

25

Ground

AIXpressor - Technical Data

Option Board MADI I/O, BNC

Option Board MADI I/O, BNC (O_DAP_MB_a)

Standards

Audio

Important - Not all sample rates are supported by the host system, please refer to the respective information.

BNC Input

BNC Output

General Features

AIXpressor - Technical Data

Option Board MADI I/O, Optical

Option Board MADI I/O, Optical (O_DAP_MO_MM_a, O_DAP_MO_SM_a)

Standards

Audio

Important - Not all sample rates are supported by the host system, please refer to the respective information.

Optical Input, LC

BNC Output

General Features

flexAIserver - Overview

flexAIserver - Overview

Physical Installation

Note - The information below applies to the pre-configured flexAIserver hardware supplied by Jünger Audio. If flexAI is installed on different server hardware, refer to the manufacturer's documentation for model-specific installation, cooling, power, and safety requirements.

The pre-configured flexAIserver is a 1RU, 19-inch rack-mount server intended for installation in a standard equipment rack.

Install the server using the appropriate rack-mounting hardware and make sure that it is adequately supported.

The server is actively cooled. Keep all ventilation openings clear and ensure sufficient airflow through the rack. Additional spacing above or below the server is normally not required unless specified by the server manufacturer or required by the cooling concept of the installation.

Power

The pre-configured flexAIserver is equipped with redundant power supplies.

Connect both power supplies for redundant operation. If one power supply fails, the remaining supply can continue to power the server.

For installations requiring high availability, connect the two power supplies to independent mains circuits whenever possible. Ideally, the circuits should also be backed by separate UPS feeds or other suitable backup power arrangements. This provides protection not only against a power supply failure, but also against the loss of one mains circuit.

Each power supply has its own mains connection and power control, depending on the installed server hardware.

Important - Please read Safety Information on proper grounding and electrical safety.

flexAIserver - Overview

Software Installation Guide Dell

Installing flexAIserver

This guide describes two methods for installing the flexAIserver software on a supported Dell PowerEdge server:

Both methods use the same flexAIserver installation image. Once the installer has started, the remaining installation procedure is identical.

Prerequisites

Before starting the installation, make sure the following are available:

For Method A – USB, you also need:

For Method B – iDRAC, you need:

Important - Installing flexAIserver erases the selected target disk. Make sure that the correct server and target disk have been selected before continuing.


Method A – USB Drive

1. Create a Bootable USB Drive

Use a suitable image-writing tool such as balenaEtcher to write the flexAIserver ISO image to a USB flash drive:

https://www.balena.io/etcher/

Important - Writing the ISO image erases all existing data on the USB drive.

When the USB drive is ready:

  1. Insert it into a USB port on the server.
  2. Connect a keyboard.
  3. Power on or restart the server.

2. Open the Boot Manager

During server startup, press F11 to open the Dell Boot Manager.

install0.png

Dell PowerEdge boot screen – press F11 to open the Boot Manager.

3. Open the One-shot UEFI Boot Menu

Select One-shot UEFI Boot Menu.

install1.png

Boot Manager – select One-shot UEFI Boot Menu.

4. Select the USB Drive

In the UEFI boot list, select the entry corresponding to the connected USB drive.

install2.png

Select the USB installation drive. USB installation only.

Continue with Common Installation Steps below.


Method B – Dell iDRAC Virtual Media

1. Map the ISO as Virtual Media

Open the Dell iDRAC Virtual Console.

In the Virtual Console, open Virtual Media and map the flexAIserver ISO image as a virtual CD/DVD.

Idrac_Virtual_Media_Mount.png

iDRAC – flexAIserver ISO mapped as Virtual CD/DVD. iDRAC installation only.

2. Restart the Server

From iDRAC, select Power > Reset System (warm boot) to restart the server and make the virtual installation media available during boot.

Idrac_WarmBoot.png

iDRAC – restart the server using Reset System (warm boot). iDRAC installation only.

3. Boot from the Virtual Optical Drive

During startup, open the Boot Manager, select One-shot UEFI Boot Menu, and then select Virtual Optical Drive.

Idrac_Boot_From_Virtual_Optical_Drive.png

Boot from Virtual Optical Drive. iDRAC installation only.

Continue with Common Installation Steps below.


Common Installation Steps

The following steps are identical for USB and iDRAC installations.

1. Start the Installer

In the GRUB menu, select Graphical install and press Enter.

install3.png

GRUB – select Graphical install. Applies to both installation methods.

2. Set the Host Name

When prompted, enter the host name to be used by the flexAIserver.

For a Jünger Audio pre-configured system, the host name can follow the device serial number, for example:

flexAIserver-00119

Alternatively, use a suitable host name according to the naming conventions of your network environment.

install4.png

Enter the host name for the flexAIserver. Applies to both installation methods.

3. Select the Target Disk

Select the internal system disk on which flexAIserver should be installed.

On Dell PowerEdge systems with a PERC RAID controller, the internal storage may appear with a name such as DELL PERC.

For USB installations, make sure that you do not select the USB installation drive.

install5.png

Select the internal system disk. Do not select the USB installation drive. Applies to both installation methods.

Important - All existing data on the selected target disk will be erased during installation. Verify the selected disk carefully before continuing.

4. Complete the Installation

Allow the installer to complete the installation process.

install6.png

Installation complete. Applies to both installation methods.

Before rebooting:

Restart the server and allow it to boot from the newly installed system disk.

Continue with the Initial Setup procedure to complete the flexAIserver configuration.

flexAIserver - Overview

Software Installation Guide HPE

HPE ProLiant DL360 Gen11

This guide describes the initial hardware configuration and installation of flexAIserver on the qualified HPE ProLiant DL360 Gen11 platform.

The server can be configured locally using a VGA monitor and USB keyboard or remotely using HPE iLO.

Important - This guide applies only to the HPE ProLiant DL360 Gen11 server qualified for flexAIserver. Do not apply the server-specific RAID, BIOS, or remote-management instructions to other hardware platforms.

Prerequisites

Before starting, make sure the following are available:

Warning - Creating the RAID volume and installing flexAIserver will erase data on the selected internal drives.


1. Initial Server Configuration

Access the Server

The server can be configured remotely through HPE iLO or locally using a monitor and keyboard.

Option A – HPE iLO Remote Access

  1. Connect a network cable to the port labelled iLO.
  2. For the initial connection, connect a monitor to the VGA port and power on the server.
  3. Note the iLO IP address shown during startup.
  4. Open the iLO IP address in a web browser.
  5. Log in using Administrator as the user name. The initial password is printed on the server top lid.
  6. In the iLO interface, open the Remote Console from the preview tile.

Screen1.png

Launch the HPE iLO Remote Console from the preview tile.

Option B – Local Access

  1. Connect a monitor to the VGA port.
  2. Connect a USB keyboard.
  3. Perform the following configuration steps directly on the local server console.

Open System Utilities

Power on or restart the server. During startup, press F9 to open System Utilities.

Prepare the SSDs for RAID1

Open:

System Utilities > System Configuration > HPE MR216io Gen11 > Main Menu > Configuration Management > Create Logical Drive

If the SSDs are listed as JBOD drives, select both internal SSDs and confirm the selection so that they can be used for the logical drive.

Screen2.png

Select both internal SSDs and confirm the selection.

Create the RAID1 Logical Drive

Set Select RAID Level to RAID1.

Choose Select Drives and verify that both internal SSDs are selected. Then select Save Configuration.

Screen3.png

Select RAID1, verify both drives, and save the configuration.

Confirm the configuration. When the logical drive has been created successfully, press Esc to return to the previous menu.

Apply the Low Latency Workload Profile

In System Utilities, open:

System Configuration > BIOS/Platform Configuration (RBSU) > Workload Profile

Select Low Latency and confirm the message.

Screen4.png

Select the Low Latency workload profile.

Press F12 to save the configuration and exit. The server restarts.

Change the Workload Profile to Custom

During the next startup, press F9 again and open:

System Utilities > System Configuration > BIOS/Platform Configuration (RBSU) > Workload Profile

Select Custom, which is the last entry in the list, and confirm the message.

Screen8.png

Select Custom as the workload profile.

Configure Virtualization Options

Open Virtualization Options and configure the settings as follows:

Screen9.png

Enable Intel VT-d and keep the other virtualization options disabled.

Press F12 to save the configuration and exit.


2. flexAIserver Software Installation

The flexAIserver software can be installed either from a bootable USB drive or remotely through HPE iLO Virtual Media.

Once the Jünger installation menu appears, the remaining installation procedure is identical for both methods.

Method A – USB Drive

Create a Bootable USB Drive

Use a suitable image-writing tool such as balenaEtcher to write the flexAIserver ISO image to the USB drive:

https://www.balena.io/etcher/

The USB drive will be erased.

  1. Insert the USB drive into a front USB port.
  2. Connect a keyboard.
  3. Power on or restart the server.
  4. During startup, press F11 to open the Boot Menu.
  5. Select the UEFI entry corresponding to the USB installation drive.

Screen6.png

Press F11 during startup and select the USB installation media.

Continue with Installation Procedure – Applies to Both Methods below.

Method B – HPE iLO Virtual Media

Map the ISO as Virtual Media

Make sure the server is powered off. If it is currently running, shut it down using the iLO power controls or the physical front-panel power button.

Launch the Remote Console as described above.

In the Remote Console:

  1. Select Virtual Media.
  2. Select CD/DVD.
  3. Select *Local .iso file.
  4. Select the flexAIserver ISO image.

Screen5.png

Open Virtual Media, select CD/DVD, and map the flexAIserver ISO image.

Boot from the Virtual Media

Keep the Remote Console open during installation. Closing it may disconnect the virtual installation media.

Power on the server using Power > Momentary Press in iLO.

Wait for the Jünger installation menu to appear.

If the server does not boot from the virtual media automatically, press F11 during startup, open the Boot Menu, and select the virtual CD/DVD or corresponding virtual-media source.


Installation Procedure – Applies to Both Methods

The following steps are identical whether the installation media is connected by USB or through HPE iLO.

Start the flexAIserver Installer

When the Jünger installation menu appears on the local display or in the Remote Console, select the available installation option, such as Graphical Install or Install, and press Enter.

Screen7.png

Select the installation option and press Enter.

Note - The Debian version and build information shown in the following example screenshots may differ from the delivered flexAIserver ISO. The installation procedure remains the same.

Set the Hostname

When prompted, enter the hostname for the flexAIserver.

For example:

flexAIserver-00119

The final digits of the device serial number may be used, or another hostname can be chosen according to the naming convention of the network environment.

install4.png

Enter the hostname for the flexAIserver.

Select the Target Disk

Select the internal RAID1 logical volume created during the initial server configuration.

Do not select the USB installation drive.

Important - The device names and capacities shown on the HPE server may differ from the generic example below. Identify the internal RAID1 logical volume by its capacity and controller information before continuing.

install5.png

Select the internal RAID1 logical volume, not the USB installation drive.

Warning - All existing data on the selected target disk will be erased during installation.

Finish the Installation

When the installer reports that the installation is complete:

Select Continue to reboot into the newly installed system.

install6.png

Installation complete – remove the physical or virtual installation media before rebooting.

After the server has booted, continue with the flexAIserver Initial Setup.

flexAIserver - Overview

Safety Information

Critical information - Please read the following safety information carefully before installing, operating, or servicing the flexAIserver hardware.

Electrical Safety

Note - The exact mains connections, power controls, and electrical specifications depend on the installed server hardware. Refer to the safety and installation documentation supplied by the server manufacturer.

Service Safety

Service work must only be carried out by suitably qualified personnel.

Before opening or servicing the server:

  1. Shut down the operating system when possible.
  2. Switch off the server.
  3. Disconnect all mains power cords.
  4. Make sure that the power cords cannot be reconnected accidentally while service work is in progress.

Do not perform internal service work while the server is connected to mains power unless the procedure is explicitly specified by the server manufacturer and is carried out by suitably qualified personnel.

Installation and Operation

Internal Battery

Server hardware may contain one or more internal lithium batteries.

Warning - Internal batteries must only be replaced with the type specified by the server manufacturer. Incorrect replacement or installation may present a risk of fire or explosion. Follow the manufacturer's instructions for replacement and disposal.

Manufacturer Safety Information

The flexAIserver software may be supplied on different qualified server platforms. Hardware-specific safety instructions, rack-mounting requirements, environmental limits, servicing procedures, and regulatory information are provided by the respective server manufacturer.

Important - Always follow the safety and installation documentation supplied with the installed server hardware. Where hardware-specific instructions differ from the general information on this page, the server manufacturer's instructions take precedence.

flexAIserver - Technical Data

flexAIserver - Technical Data

tieLight portal PCIe

tieLight Portal PCIe – tieLight and MADI I/O Card (O_Serv_AI_MADI_TIE_a)

The tieLight Portal PCIe card provides optical tieLight and MADI audio I/O together with an external synchronization input.

Standards

Audio

Important - Not all sample rates may be supported by the host system. Refer to the specifications of the respective flexAI system.

Optical Input

Optical Input Power
Optical Module Fiber Type Input Optical Power
O_DAP_MO_MM_a OM2 multimode, 50/125 µm -31 to -8 dBm
O_DAP_MO_SM_a Single-mode -23 to -8 dBm

Other single-mode variants may be available on request.

Maximum Cable Length
Optical Module Fiber Type Maximum Cable Length
O_DAP_MO_MM_a OM2 multimode 1.5 km
O_DAP_MO_SM_a Single-mode 2 km

The values shown for the single-mode module are the standard specifications. Other variants may be available on request.

Sync Input

The card provides a multi-standard external synchronization input supporting AES/EBU, Word Clock, Black Burst, and Tri-Level Sync.

The synchronization interface complies with AES11-2009 and the relevant audio and video synchronization standards.

General Features